Production Scientifique 2011-2017
   

Articles revues internationales avec comité de lecture

Boufi M., Guivier-Curien C., Loundou A.D., Deplano V., Boiron O., Chaumoitre K., Gariboldi V., Alimi Y.S.
Morphological analysis of healthy aortic arch.
Accepted in the European Journal of Vascular and Endovascular Surgery, 2017.

Deplano V, Boufi M, Boiron O, Guivier-Curien C, Alimi Y, Bertrand E.
Biaxial tensile tests of porcine ascending aorta.
Journal of Biomechanics, 2016, 49(10), 2031-2037.

Zhu W, Knapp Y, Deplano V.
Low hazard refractive index and density matched fluid for quantitative imaging of concentrated suspensions of particles.
Experiments in Fluids, 2016, 57:68.

Boufi M, Guivier-Curien C, Dona B, Loundou A, Deplano V, Boiron O, Hartung O, Alimi Y.
Risk Factor Analysis for the Mal-Positioning of Thoracic Aortic Stent Grafts.
European Journal of Vascular and Endovascular Surgery, 2016, 52(1), 56-63

Boufi M, Guivier-Curien C, Deplano V, Boiron O, Loundou A, Dona B, Hartung O, Alimi Y.
Risk factor analysis of bird beak occurrence after thoracic endovascular aortic repair.
European Journal of Vascular and Endovascular Surgery, 2015, Vol 50: 37-43

Boufi M, Aouini F, Guivier-Curien C, Deplano V, Anderson L, Hartung O, Dona B, Alimi Y.
The influence of emergency anatomical and stent-graft related factors on type I endoleak development after thoracic aortic endografting.
Journal of Vascular Surgery, 2015, Vol 61(2): 317-323

Ghiss M, Giannesini B, Tropiano P, Tourki Z, Boiron O.
Quantitative MRI water content mapping of porcine intervertebral disc during uniaxial compression.
Computer Methods in Biomechanics and Biomedical Engineering, 2015, 1-10

Scheinherr A, Bailly L, Boiron O, Lagier A, Legou T, Pichelin M, Caillibotte G, Giovanni A.
Realistic glottal motion and airflow rate during human breathing.
Medical Engineering & Physics, 2015, Vol 37(9):829-839

Macek Jilkova Z, Lisowska J, Manet S, Verdier C, Deplano V, Geindreau C, Faurobert E, Albigès-Rizo C, Duperray A.
CCM proteins control endothelial EA.hy946 Beta1 integrin dependent response to shear stress.
Biology open, 2014, Vol 3(12): 1228–1235

Bailly L, Toungara M, Orgéas L, Bertrand E, Deplano V, Geindreau C.
In-plane mechanics of soft architectured fibre-reinforced silicone rubber membranes.
Journal of the Mechanical Behavior of Biomedical Materials, 2014, Vol 40: 339–353

Deplano V, Knapp Y, Bailly L, Bertrand E.
Flow of blood analogue fluid in a compliant abdominal aortic aneurysm model : experimental modelling.
Journal of Biomechanics, 2014, Vol 47(6): 1262-1269

Bailly L, Henrich N, Müller F, Rohlfs AK, Hess M.
The ventricular-fold dynamics in human phonation.
Journal of Speech, Language, and Hearing Research, 2014, Vol 57: 1219-1242

Bailly L, Deplano V, Lemercier A, Boiron O, Meyer CA.
New experimental protocols for tensile testing of abdominal aortic analogs.
Medical Engineering and Physics, 2014, Vol 36: 800-804

Deplano V, Meyer C, Guivier-Curien C, Bertrand E.
New insights into the understanding of flow dynamics in an in vitro model for abdominal aortic aneurysms.
Journal of Medical Engineering & Physics, 2013, Vol 35(6): 800-809

Boiron O, Guivier-Curien C, Bertrand E.
Study of the hydrodynamic of a flapping foil at moderate angle of attack.
Computers and Fluids, 2012, Vol 59: 117-124

Bailly L, Geindreau C, Orgéas L, Deplano V.
Towards a biomimetism of abdominal healthy and aneurysmal arterial tissues.
Journal of Mechanical Behaviour Biomedical Materials, 2012, Vol 10: 151-165

Fahd G, Mokhtar OA, Boiron O, Morgado I, Paganelli F. Otal P, Deplano V.
Design of a secondary standard for measuring arterial Blood Pressure.
Measurement, 2012, Vol 45: 2490-2493

Meyer C, Bertrand E, Boiron O, Deplano V.
Stereoscopically Observed Deformations of a Compliant Abdominal Aortic Aneurysm Model.
Journal of Biomechanics Engineering Transactions of the ASME, 2011, Vol 133, 11, 111004

ENDOCOM. (2011). Implantable wireless pressure sensor for the follow-up of abdominal aortic aneurysm stented.
Publication écrite au nom du consortium ENDOCOM. IRBM, 32, 163-168

ITOV (2011). Development of a new bone tissue-engineered product.
Publication écrite au nom du consortium ITOV. IRBM, 32, 87–90

haut de page


Actes de Congrès

Deplano V, Boufi M, Boiron O, Alimi Y, Bertrand E.
Mechanical characterization of porcine ascending aorta.
Computer Methods in Biomechanics and Biomedical Engineering, 2015, Vol 18: 1922-1923

Zhu W, Knapp Y, Deplano V.
Characterization of dense particle suspensions under flow.
Computer Methods in Biomechanics and Biomedical Engineering, 2015, Vol 18: 2088-2089

Chetoui M, Boiron O, Dogui A, Deplano V.
IVD nutrition processes under compressive load: a finite deformation model.
Computer Methods in Biomechanics and Biomedical Engineering, 2015, Vol 18: 1898-1899

Guivier-Curien C, Boufi M, Deplano V, Boiron O, Loundou A, Alimi Y.
Thoracic aorta morphometry and endograft deployment.
Computer Methods in Biomechanics and Biomedical Engineering, 2014, Vol 17: 10-11

Etienne M, Deplano V, Boiron O, Tropiano P.
3D dynamic numerical simulations of intervertebral disc: bending and twisting.
Computer Methods in Biomechanics and Biomedical Engineering, 2013, Vol 16: 236-238

Toungar M, Orgéas L, Geindreau C, Bailly L.
Micromechanical modelling of the arterial wall: influence of mechanical heterogeneities on the wall stress distribution and the peak wall stress.
Computer Methods in Biomechanics and Biomedical Engineering, 2013, Vol 16(S1): 22-24

Knapp Y, Deplano V, Bertrand E.
A simple model for the perfusion of porous hydrogel scaffolds under culture in a sustentation like bioreactor.
Computer Methods in Biomechanics and Biomedical Engineering, 2013, Vol 16: 268-269

Lemercier A, Bailly L, Geindreau C, Toungara M, Latil P, Orgéas L, Deplano V, Boucard N.
Comparison between the mechanical behavior of the human healthy AA and commercial prostheses under various mechanical loadings.
Computer Methods in Biomechanics and Biomedical Engineering, 2013, Vol 16: 315-317

Macekjilkova Z, Deplano V, Verdier C, Toungara M, Geindreau C, Duperray A.
Wall shear stress and endothelial cells dysfunction in the context of abdominal aortic aneurysms.
Computer Methods in Biomechanics and Biomedical Engineering, 2013, Vol 16: 27-29

Scheinherr A, Bailly L, Boiron O, Legou T, Giovanni A, Caillibotte G, Pichelin M.
Glottal motion and its impact on the respiratory flow.
Computer Methods in Biomechanics and Biomedical Engineering, 2012, Vol 15(S1): 69-71

Deplano V, Bailly L, Bertrand E.
Influence of blood shear-thinning behaviour on flow dynamics in abdominal aortic aneurysm in vitro compliant model.
Computer Methods in Biomechanics and Biomedical Engineering, 2012, Vol 15: 49-52

Knapp Y, Deplano V, Bertrand E.
Flow dynamics characterisation of a novel perfusion type bioreactor for bone tissue engineering.
Computer Methods in Biomechanics and Biomedical Engineering, 2012, Vol 15: 116-119

Etienne M, Boiron O, Tropiano P, Deplano V.
Nutrient convection and diffusion modelling in the intervertebral disc.
Computer Methods in Biomechanics and Biomedical Engineering, 2011, Vol 14: 45-146

Fahd G, Mokhtar OA, Boiron O, Morgado I, Paganelli F, Deplano V.
Comparing invasive and oscillometric blood pressure measurements.
Computer Methods in Biomechanics and Biomedical Engineering, Vol 14: 149-151

haut de page


Congrès Internationaux (*) et Nationaux

Boufi M, Guivier-Curien C, Dona B, Hartung O, Deplano V, Boiron O, Alimi Y.
Mal-positionnement des endoprothèses de l'aorte thoracique lors du largage: quantification, causes et conséquences.
XXXe Congrès de Société de Chirurgie Vasculaire, 26-29 juin 2015, Montpellier.

Guivier-Curien C, Bertrand E, Deplano V.
Etude des écoulements intra anévrismaux par PIV stéréoscopique.
CFM, Lyon, Aout 2015

* Bailly L, Toungara M, Orgéas L, Bertrand E, Deplano V, Geindreau C.
In-plane mechanics of elastomeric fibrous composite membranes: cases of straight fibres and wavy bundle of fibres
EUROMECH 560: Mechanics of biological membranes, 8-11 february 2015, Suisse

* Bailly L, Toungara M, Orgéas L, Bertrand E, Deplano V, Geindreau C.
In-plane mechanics of elastomeric fibrous composite membranes:cases of straight fibres and wavy substructure
EUROMECH Colloquium 560: Mechanics of Biological Membranes, February 2015, Centro Stefano Franscini, Monte Verità, Ascona, Switzerland

Boiron O, Scheinherr A, Bailly L.
Transport et dépôt d'aérosols liquides dans les voies aériennes supérieures.
22th Congrès Français de Mécanique (CFM'20), Lyon, 24-28 août 2015

* Boiron O, Scheinherr A, Elliott AR, Bailly L, Theilmann RJ, Darquenne C.
Dynamics of the glottis during breathing.
20th Congress of the International Society for Aerosols in Medicine, Munich, 30th May-3rd June 2015.

* Lemercier A, Bailly L, Geindreau C, Orgéas L, Deplano V, Boucard N.
Optimizing Textile Architectures to Improve the Mechanical Behaviour of Textile Aortic Prostheses.
7th World Congress of Biomechanics, Boston, Juillet 2914

* Belka M, Jedelsky J, Boiron O, Bailly L, Bertrand E, Zaremba M, Maly M, Lizal F.
Measurement of Airflow in Trachea using Particle Image Velocimetry and Laser-Doppler Anemometry.
20th International Conference Engineering Mechanics, Svratka, République Tchèque, 12-15 mai 2014

* Scheinherr A, Bailly L, Boiron O, Legou T, Lagier A, Caillibotte G, Pichelin M.
Laryngeal two-phase flow in realistic breathing conditions
19th congress of the European Society of Biomechanics, Patras, Grèce, 25-28 août 2013.

* Scheinherr A, Lagier A, Bailly L, Boiron O, Legou T, Giovanni A, Amy de la breteque B, Caillibotte G, Pichelin M.
Glottal motion and its impact on inhaled aerosol deposition in upper airways
19th congress of the International Society for Aerosols in Medicine, Chapel Hill, University of North Carolina, USA, 06-10 avril 2013. Journal of aerosol medicine and pulmonary drug delivery, 26(2) A27.

*Ait Mouheb N, Bailly L, Boiron O, Bertrand E.
Local aerosol deposition and gas-flow in vitro measurements using PIV-LIF techniques.
19th congress of the International Society for Aerosols in Medicine, Chapel Hill, University of North Carolina, USA, 06-10 avril 2013. Journal of aerosol medicine and pulmonary drug delivery, 26(2) A27.

* MacekJilkova Z, Faurobert E, Lisowska J, Verdier C Deplano V, Geindreau G, Albigès-Rizo C, Duperray A.
Shear stress and CCM complex antagonistically regulate β1 integrin-dependent cytoskeleton remodeling of endothelial cells.
Invadosomes : "Cell migration and invasion in physiology and pathology", 13-17 Octobre 2013, Nijmegen, the Netherlands.

* Bailly L, Lemercier A, Geindreau C, Orgéas L, Deplano V.
Biomimetism of abdominal healthy and aneurysmal arterial tissues: Microstructure Optimisation and Processing.
Journées Dysco2013 – 13-14 Janvier 2013.

Bailly L, Lemercier A, Geindreau C, Orgéas L, Deplano V.
Architectured Soft Fibre-Reinforced Membranes Mimicking Arterial Tissues : Microstructure Optimisation and Processing.
Société Française de métallurgie et de matériaux. Proceeding dans Matériaux et Techniques, 100, 2012.

* Macekjilkova Z, Duperray A, Verdier C, Ballet P, Deplano V, Toungara M, Geindreau C.
Wall shear stress and cells dysfunction in the context of abdominal aortic aneurysm.
4th Workshop "nano and micro environments for cell biology, Grenoble, 2012.

* Lemercier A, Bailly L, Geindreau C, Orgéas L, Deplano V.
On the development of new artificial materials mimicking aortic tissue histological and mechanical features.
Euromech 534, Advanced Experimental Approaches and Inverse Problems in Tissue Biomechanics. 9-13 Juillet 2012, Graz, Autriche.

* Bailly L, Lemercier A, Geindreau C, Orgéas L, Deplano V.
Towards New Aortic Tissues Analogue Materials: Micro-mechanical Modelling and Experiments.
8th European Solid Mechanics Conference, ESMC2, 29-31 mai 2012, St Etienne, France.

* Garda P, Mazeyrat J, Romain O, Talleb H, Lautru D, Wong MF, Wiar TJ, Hanna VF, Lagrée PY, Bonneau M, Kang C, Fernandez M, Gerbeau JF, Deplano V, Legallais C, Leprince P.
RFID implantable pressure sensor for the follow-up of abdominal aortic aneurysm stended.
IEEE DTIS : 6th International Conference on Design and Technology of Integrated Systems in nanoscale era on CD-ROM, 2011.

* Fahd G, Mokhtar OA, Boiron O, Morgado I, Paganelli F, Otal P, Deplano V.
Creating a calibrating chain in order to evaluate automated blood pressure devices.
15th International Congress of Metrology, octobre 2011, Paris.

* Bailly L, Boiron O, Legou T, Giovanni A, Caillibotte G.
Glottal dynamics and laryngeal airflow during human breathing.
Pan European Voice Conference (PEVOC'09), Marseille, France, 31 août 2011.

* Chevaillier G, Bailly L, Henrich N.
Ventricular folds in speech and singing: physiology, use, physical and perceptual impact.
Pan European Voice Conference (PEVOC'09), Marseille, France, 31 août 2011.

haut de page


Conférences Invitées

Deplano V.
De la dynamique des fluides aux anévrismes de l'aorte abdominale.
Conférence plénière invitée, Congrès de la Société de Biomécanique, Paris, Octobre 2015

Deplano V.
Modélisation in vitro des écoulements dans un anévrisme de l’aorte abdominale.
Journées CNRS INSIS "Ecoulements biologiques", Paris, Juillet 2015

* Deplano V, Knapp Y, Guivier-Curien C, Bertrand E.
Experimental modeling of the flow dynamics within an abdominal aortic aneurysm.
7th World Congress of Biomechanics, Boston, Juillet 2014

haut de page



Drupal 7 Appliance - Powered by TurnKey Linux